AWC 140 A Liquid Ring Vacuum Pump, 5.599 kW (@60 Hz), CI/SS - Stainless Fitted, Once Through Version

1951002088

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Pressure Differential Max @60Hz Variant Liquid Ring Pump Material
1951002048 - CI/SS - Stainless Fitted
1951002054 - SS - Stainless Steel
1951002088 560.00 CI/SS - Stainless Fitted

Liquid Ring Pumps Single-Stage Plate

Liquid ring vacuum pumps are positive displacement pumps that use a ring of liquid to create a seal between the vanes or impeller and the pump housing, creating a vacuum and pumping gas or vapor out of a chamber. They are rugged, reliable and widely used in applications ranging from chemical processing, paper and pulp industry, power generation, and wastewater treatment. They are also very suitable for humid application, contributed by their high handling capacity of condensable vapor.

AWC A

The Atlas Copco AWC standard liquid ring pump/systems are high performance, low maintenance, pre-engineered liquid ring pump systems that are ideal for use in a range of industrial vacuum applications. Especially where the process contains high levels of vapor, liquid carry-over or contamination by solids. Efficient and modular in design, the AWC range of standard LRP systems offer a flexible solution that is both robust and reliable while allowing for up to 95% water savings over traditional LRP in once-through seal liquid operation

AWC 140 A

single stage liquid ring pump, nominal pumping speed is 79 ACEF @50Hz

Features and Benefits

  • State-of-the-art bearing design allowing for reduced clearances and improved suction performance
  • Variable area discharge porting for optimum efficiency across all inlet pressures
  • Motor-mounted pumps feature economical UL/CS EPACT compliant motors
  • Sturdy bearing pedestal mounts to standard NEMA, C-face motor
  • 316 stainless steel impeller as standard
  • Mechanical seals as standard
  • Robust, reliable, low maintenance construction
  • Modular design of 3 package types: once-through, partial recirculation and total recovery
  • Optional materials of construction: stainless steel fitted and stainless steel complete
  • Atlas Copco quality approved accessories
  • Minimum life cycle costs and optimized reliability
  • Low noise level

General Product Information

Dimension Length 0.635
Dimension Height 0.402
Dimension Width 0.330
Connection Inlet Flange DN 40
Noise / Sound Level 74.00 db(A)
Power Supply Frequency 60 Hz
Weight 97.07
Power Supply Phase 3-Ph
Cooling Method Water Cooling
Connection Outlet Flange DN 40
Connection Cooling 3/8'' FNPT
IP Rating IP54
Connection Inlet / Outlet Flange DN 40 / DN 40

Performance Data

Pressure Backing Max 20000.00
Pressure Ultimate 3000.00
Power Total Rated 5599.00
Power Total Rated @60Hz 5600.00
Pressure Differential Max @60Hz 560.00
Displacement @60Hz Max 0.046

Operation Conditions - Limitations

Pressure Absolute Inlet Continous Max 1.013 × 10⁵
Altitude Max 1.00
Temperature Inlet Gas Max 100.00
Flow Cooling Water Min 2.056 × 10⁻⁴
Pressure Absolute Outlet Continous Max 1.200 × 10⁵

Environmental Conditions

Temperature Ambient Operation Max 50.00
Temperature Ambient Operation Min -20.00

Classification

Classification High / Medium / Rough Vacuum pump Rough Vacuum Pump
Classification Dry or Wet Pump Wet
Classification Vacuum Pump Technology Liquid Ring Pump
Classification Product Pressure Range Rough Vacuum: 1000 mbar - 1 mbar

Variants

Variant Liquid Ring Pump Material CI/SS - Stainless Fitted
Variant LRP Pump Configuration Once Through Version